Omron SYSDRIVE RX Series User Manual page 309

High-function general-purpose inverter
Table of Contents

Advertisement

Register
Function name
No.
1460h
to
Not used
1468h
1469h
UP/DWN selection
146Ah
Reset selection
Reset frequency matching
146Bh
selection
146Ch
Not used
146Dh
MP gain setting
146Eh
AM gain setting
146Fh
AMI gain setting
1470h
Not used
1471h
AM bias setting
1472h
AMI bias setting
1473h
Overload warning level 2
1474h
to
Not used
147Ch
147Dh
FV zero adjustment
147Eh
FI zero adjustment
147Fh
FE zero adjustment
1480h
to
Not used
1485h
Function
R/W
Monitor and setting parameters
code
0: Does not store the frequency data
C101
R/W
1: Stores the frequency data
0: Trip reset at power-on
1: Trip reset at power-off
C102
R/W
2: Enabled only during trip (Reset at
power-on)
3: Trip reset only
0: 0-Hz start
C103
R/W
1: Frequency matching start
2: Frequency pull-in restart
C105
R/W
50 to 200
C106
R/W
50 to 200
C107
R/W
50 to 200
C109
R/W
0 to 100
C110
R/W
0 to 100
0 to 2000 (0.4 to 55 kW)
C111
R/W
0 to 1800 (75 to 132 kW)
C121
R/W
0 to 65530
C122
R/W
0 to 65530
C123
R/W
0 to 65530
4-4 Communication Function
Resolution
4
1 [%]
1 [%]
1 [%]
1 [%]
1 [%]
0.1 [%]
1
1
1
4-200