I/O Number Assignment - Mitsubishi 00JCPU User Manual

Q series programmable controller
Table of Contents

Advertisement

4.2 I/O Number Assignment

The I/O number indicates addresses used for sequence programs in the following cases.
• Input of on/off data to the CPU module
• Output of on/off data from the CPU module to the external device
(1) Input and output of on/off data
The input (X) is used to input on/off data to the CPU module, and the output (Y) is used to output on/off data from
the CPU module.
(2) I/O number representation
I/O number representation
When a 16-point I/O module is used, the I/O number for each slot will be 16 point-sequence number from
to
F as shown in Figure 4.4.
"X" and "Y" is prefixed to the I/O number of input modules and the I/O number of output modules, respectively.
Power supply
4 - 4
For the case of input
module
X
0
0
0
X
0
1
0
X
0
2
X
0
0
F
X
0
1
F
X
0
2
16 input
16 input
16 input
points
points
points
CPU module
Figure 4.4 I/O numbers
For the case of
output module
0
Y
0
3
0
Y
0
4
0
F
Y
0
3
F
Y
0
4
F
16 output
16 output
points
points
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents