4 . USER SCREEN MODE
Guide to Screen Objects
Display example
HEATlNGTlME
Text
PROCESS 1
89.6 sec.
Number
Changing displayed data
It is possible to change displayed numerical data (for details, see page 44).
(4) BAR GRAPH
This object displays programmable controller
word
devices (T and C current values and settings,
D, V, Z) in the form of a bar graph. This form of presentation makes the information easy to read
at a glance.
Applicable devices
T, C (current values, settings), D (16-bit), D (32-bit), V, 2.
Display format
The bar graph can be displayed either vertically or horizontally.
.
It is possible to set maximum and minimum values for the current value of the displayed device.
The current value is displayed as a percentage, taking the minimum as 0% of the set area and
the maximum as 100% of the set area.
If the data value is lower than the minimum or higher than the maximum, a diagonal line will
appear across the bar graph.
Example
Specified programmable controller device : D l
MAX.:
3000
MIN.:
1000
Current value
=
1,500
Current value
=
0
Horizontal presentation
on 40DU screen
Vertical presentation
on 40DU screen
MIN
CURRENT
MAX
(1 000)
(1 500)
(3000)
,
MAX
MIN
CURRENT
-