Mitsubishi 00JCPU User Manual page 342

Q series programmable controller
Table of Contents

Advertisement

CHAPTER8 PARAMETERS
This chapter describes the parameters required to be set for configuring a programmable controller system.
(1) Parameter types
The following parameters are provided for CPU module setting.
• PLC parameters (
These parameters are set when a programmable controller is used.
• Redundant parameters (
These parameters are set when a redundant system is configured using the Redundant CPU.
• Network parameters (
These parameters are set when a programmable controller module is used in combination with any of CC-
Link IE Controller Network modules, MELSECNET/H modules, Ethernet modules, and CC-Link modules.
• Remote password (
Parameters are set when the remote password function is used for an Ethernet module, serial
communication module, and modem interface module.
(2) Parameter setting method
Use GX Developer.
For the setting details, refer to the following.
GX Developer Version 8 Operating Manual
Grayed-out (unselectable) parameter settings in GX Developer are not available since the corresponding function is not
supported.
Remark
Each parameter number shown in the tables in this chapter is stored in the special register (SD16 to SD26) when an error
occurs in parameter setting.
Identify the parameter error location from the parameter number.
For the list of the special register (SD16 to SD26), refer to the following.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
For the parameter updating procedure, refer to CHAPTER 11.
8 - 1
Section 8.1)
Section 8.2)
Section 8.3)
Section 8.4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents