Mitsubishi 00JCPU User Manual page 217

Q series programmable controller
Table of Contents

Advertisement

(3) Switch settings
Set the switch details for each intelligent function module and interrupt module in the I/O assignment tab of the
PLC parameter dialog box.
1) Make I/O assignment for the target module.
2) Click the
Switch setting
3) Set the switch details for each module.
1) Make I/O assignment.
(4) Precautions
(a) When an AnS/A series-compatible module is used
Do not set the switch details for AnS/A series-compatible special function modules.
Even if values are input, the setting is ignored.
(b) Switch setting details of each module
For the switch setting details of each intelligent function module or interrupt module, refer to the manual for the
intelligent function module or interrupt module used.
(c) Setting differences between GX Developer versions
Set the following type for interrupt modules depending on the version of GX Developer.
• GX Developer Version 6 (SW6D5C-GPPW-E) or later: "Interrupt"
• GX Developer Version 5 (SW5D5C-GPPW-E) or earlier: "Intelli."
(d) Enabling the setting
The switch settings of each intelligent function module or interrupt module will be enabled when:
• the CPU module is powered off and then on, or
• the CPU module is reset.
Note6
Note6.2
Basic
The Basic model QCPU, Process CPU and Redundant CPU do not support the use of AnS/A series-compatible input
modules or interrupt modules.
button.
2) Click the Switch setting button.
Figure 6.26 Switch settings
Process
Redundant
3)
Set the switch details of each intelligent
function module and interrupt module.
Note6
Note6.2
CHAPTER6 FUNCTIONS
6 - 37
1
2
3
4
5
6
7
8