Program Alarms - Honeywell ACUIX User Manual

High speed dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Document 800-01023 Rev A
02/08
Example:
When the ACUIX dome is set at 12X zoom, the pan and tilt functions are very
slow.
Auto-Pivot
If the Auto-Pivot feature is on, the pan and tilt unit automatically pans the camera 180°
when the camera reaches vertical. This feature is used to assist the operator in tracking
an individual that passes directly under the camera.
To toggle Auto-Pivot ON or OFF (default), select 2 from the Control Options menu.
To perform this function:
1.
Position the camera lens so it is not vertical.
2.
Using the joystick on the controller, tilt the camera down until the camera lens is
vertical (pointing at the floor) and continue tilting down with the controller.
3.
The pan and tilt unit pans the camera 180° and then begins to tilt up. It continues to
tilt up as long as the controller tilt function remains in the down position. When the
ACUIX reaches its tilt up limit, the dome returns to normal operation.
If the controller is returned to its neutral position before the ACUIX reaches its tilt up limit,
the ACUIX returns to normal operation.

Program Alarms

The ACUIX has four alarm inputs for normally open or closed dry contacts. When a
contact changes from its normal state, an alarm occurs. Alarms can be enabled or
disabled. The ACUIX can be programmed to go to a Preset, start a Preset Tour, or start a
Mimic Tour when an alarm occurs and the alarm is enabled.
Select 3 from the Control Options menu to
program the alarms. The Program Alarms
screen displays.
ACUIX High Speed Dome User Manual
PROGRAM ALARMS
1 Program Alarms
2 Set Alarm Condition
ESC to Exit
93