12.6 ERRATIC SCAN OPERATION

Possible
1. Verify that communication termination jumpers on the board in the back can or top
solution:
dome are set properly.
Home-Run Wiring – one scan per control output
• Jumpers W1 and W2 are installed in the TERM position.
Daisy-Chain Wiring – more than one scan per control output
• Jumpers W1 and W2 are installed in the TERM position on the last back can
• Jumpers W1 and W2 are installed in the UNTERM position on all
2. Verify data lines are not broken and are connected properly at the terminal strip in
the back can or top dome.
UTC Option – verify jumpers W3 & W4 in back can/top dome are in positions 2 & 3.
CAT5 Option – verify jumpers W3 & W4 in back can/top dome are in positions 1 & 2.
3. See

12.7 LENS OUT OF OPTICAL FOCUS

Possible
1. A function has been added to reset the camera lens (zoom and focus).
solution:
Pre-programmed PreShots activate this function:
If using:
Standard KD6i, Maxpro mode, Pelco protocols, Burle, VCL
American Dynamics
American Dynamics switcher using Pelco protocol
2. This can also be caused by dirt, oil, grease, fingerprints, etc. on the lens or dome.
Check the lens and dome and clean if needed.
3. Verify that the lens cap is not on the camera. A translucent cap may be in place
and will blur the camera if not removed.
Rev. D
or top dome on the data run.
intermediate back cans or top domes.
12.4, possible solution