Prs-Nsp Network Splitter - Bosch DCN Next Generation Installation And Operation Manual

Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

Conference System
7.17

PRS-NSP Network Splitter

The rear of the cover of the network splitter shows a label that gives data of the internal
connections. You can change the internal connections with the jumper blocks inside the
network splitter.
Figure 7.27 Label inside network splitter
To supply additional power to the tap-offs that are connected to the network splitter:
1.
2.
3.
Bosch Security Systems B.V.
9
10
3 4 5
6 7 8
1
2
Put jumper shunt 1/2 on position 2.
Put jumper shunt 9/10 on position 9.
Connect an external power supply to the network splitter (refer to Section 6.25 PRS-
FINNA Fiber Interface).
Installation and Operation manual
11
12
Main network
Tap-off powered
from:
External power
0.8 A
Current limit
Tap-off 1
1.6 A
2.5 A
0.8 A
Current limit
Tap-off 2
1.6 A
2.5 A
On
External power
follows
Main network
Fault
LED
Power
DCN-NG_IOM_V4.1 | V1.3 | 2012.07