268 en | Technical Data
11.1.6

Miscellaneous

Basic standard ESD:
Basic standard mains harmonics and
voltage fluctuations, flicker:
Basic standard RF electromagnetic
fields:
Magnetic immunity:
Basic standard low energy electrical
fast transients, bursts:
Basic standard high energy surges:
Basic standard voltage dips, short
interruptions, variations:
Shock resistance:
Vibration resistance:
Working conditions:
Temperature range:
Relative humidity:
DCN-NG_IOM_V4.1 | V1.3 | 2012.07
According EN 61000-4-2.Contact discharge: 4 kV
and air discharge: 8 kV
According EN 61000-3-2 and EN 61000-3-3
According EN 61000-4-3RF conducted: 150 kHz -
80 MHz: 3 VrmsRF radiated 80 - 1000 MHz: 3 V/m
Cellular telephone (GSM) dummy test: at 20 cm
speech distance. Criteria: not effecting normal
operation.
Rack mounting: 50 Hz - 10 kHz: 4 - 0.4 A/m No rack
mounting: 50 Hz - 10 kHz: 3 - 0.03 A/m
According EN 61000-4-4Mains: fast transients: 1
kV; signal and control data lines: 0.5 kV
According EN 61000-4-5Mains: surges: 1 kV CM
and 0.5 kV DM.
According EN 61000-4-11Mains: voltage dips
100% for 1 period, 60% for 5 periods, > 95% for 5
seconds.
According to IEC 68.2.29 Eb
According to IEC 68.2.6 Fc, procedure A
Fixed, stationary, transportable
< 95%
Installation and Operation manual
-20 to +70 °C (transport)
+5 to +45 °C (operation)
For EPS and contribution devices with an
LCD, the maximum temperature is +40 °C.