Bosch DCN Next Generation Installation And Operation Manual page 199

Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

Conference System
Bundles
The CobraNet network uses bundles for the transport of audio signals. The cobranet interface
can:
Receiver bundles
Each receiver bundle can have 8 bundle channels. To the bundle channels of a receiver
bundle, you can connect the audio inputs of the cobranet interface. Thus, the audio inputs
take audio signals from the CobraNet network and send them to the optical network.
Do as follows to configure a receiver bundle of the cobranet interface:
1.
2.
3.
Figure 7.9 Rx Advanced Configuration window
4.
5.
Bosch Security Systems B.V.
Receive 4 bundles from the CobraNet network (receiver bundles). Refer to the Receiver
blocks in the figure.Send 4 bundles to the CobraNet network (transmitter bundles). Refer
to the Transmitter blocks in the figure.
Go to the Advanced Configuration window of CNConfig.
In the Bundle Number field of the receiver bundle, enter the number of the bundle that
the receiver bundle must take from the CobraNet network.
Double-click on the first bundle channel (Ch 1) with the left mouse button. CNConfig
shows an Rx Advanced Configuration window. With the Rx Advanced Configuration
window, you can change the audio inputs that are connected to the bundle channels.
On the right side of the Bundle Channel 1 block, click the arrow button with the left
mouse button. The CNConfig shows a list of audio inputs that can connect the bundle
channel 1.
Click the audio input that must be connected to the bundle channel. When the cobranet
interface does not use the bundle channel, click on Unused with the left mouse button.
Installation and Operation manual
Configuration | en 199
DCN-NG_IOM_V4.1 | V1.3 | 2012.07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcn series

Table of Contents