BATTERY
RE MOVAL/IN STALLATI O N
Remove the seat (page 2-21,
Always turn the
ignition switch to
"OFF" before
Remove the battery holder band.
removing the bat-
Disconnect the negative cable and then the positive
terv
cable, and remove the battery.
Install the battery in the reverse order of removal with
Connect the posi-
tive terminal first
the proper wiring as shown.
and then the neg-
ative cable
After installing the battery, coat the terminals with
clean dielectric grease.

VOLTAGE INSPECTION

Measure the battery voltage using a digital multime-
ter.
VOLTAGE:
Fully charged: 13.0
Under charged: Below 12.3V
TOOL:
Digital multimeter

BATTERY TESTING

Always clear the work area of flammable materials
such as gasoline, brake fluid, electrolyte, or cloth
towels when operating the tester, the heat generat-
ed by the tester may cause a fire.
Remove the battery (see above)
Securely connect the tester's positive
then connect the negative
TOOL:
Battery tester
Set the temperature switch to "HIGH" or "LOW"
depending on the ambient temperature.
-
Commercially
available
cable first,
(+)
cable.
BM-210-AH or BM-210
(U.S.A. only)
NEGATIVE TERMINAL
HOL
TESTER
BLACK
HIGH:
15°C
(60°F)
or higher
LOW:
(60°F) or lower
15°C
POSITIVE TERMINAL
RY
BATTERY
BATTERY