SmartStor NAS Product Manual
2. Click the OK button.
The time setting is applied.
Viewing UPS Status
If you have an APC Uninterruptable Power Supply (UPS) attached to the
SmartStor, you can check its status in WebPASM.
To view UPS status:
1. Click the Administration topic and choose the Management icon to expand
the Tree.
2. In the Tree, click the APC UPS icon.
The Information tab displays the status of the UPS.
If there is no UPS connected or recognized, the Status field reports "NO
UPS."
Setting up a UPS
This feature enables you to tell the SmartStor how long to run on UPS battery
power and when to shutdown, after a power failure.
To set up a UPS:
1. Attach the APC UPS to one of the SmartStor's USB ports.
2. Click the Administration topic and choose the Management icon to expand
the Tree.
3. In the Tree, click the APC UPS icon.
4. Click the Setup tab.
5. Click the option button beside the shutdown option you want:
Disable - Run until the UPS battery is depleted
․
Run until the UPS battery reaches a certain percentage
․
Run on the UPS battery for certain period of time
․
If you chose battery percentage, type a percentage amount in the % field.
If you chose running time, type the number of minutes into the Mins. field.
6. Click the OK button.
7. In the confirmation box, click the OK button.