Autoprovisioned
An Autoprovisioned firmware upgrade only happens after a reboot, will take roughly three minutes,
Firmware Upgrades
and the web page will be unresponsive during this time.
The 'FirmwareVersion' value in the xml file must match the version stored in the 'FirmwareFile'.
<FirmwareVersion>v10.1.3</FirmwareVersion>
<FirmwareFile>1013-intercom-uImage</FirmwareFile>
If these values are mismatched, the board can get stuck in a loop where it goes through the following
sequence of actions:
1. The board downloads and writes a new firmware file.
2. After the next reboot, the board recognizes that the firmware version does not match.
3. The board downloads and writes the firmware file again.
CyberData has timed a firmware upgrade at 140 seconds. Therefore, if you suspect the board is
stuck in a loop, either remove or comment out the FirmwareVersion line in the XML file and let the
board boot as it normally does.
Autoprovisioned
Audio files are stored in non-volatile memory and an autoprovisioned audio file will only have to be
Audio Files
downloaded once for each device. Loading many audio files to the device from the web page could
cause it to appear unresponsive. If this happens, wait until the transfer is complete and then refresh
the page.
The device uses the file name to determine when to download a new audio file. This means that if
you used autoprovisioning to upload a file and then changed the contents of this file at the TFTP
server, the device will not recognize that the file has changed (because the file name is the same).
Since audio files are stored in non-volatile memory, if autoprovisioning is disabled after they have
been loaded to the board, the audio file settings will not change. You can force a change to the audio
files on the board by clicking Restore Default on the Audio Configuration page or by changing the
autoprovisioning file with "default" set as the file name.
Operations Guide
After rebooting, the board will configure itself according to this new file.
930947A
Installing the VoIP Emergency Intercom
Configure the Autoprovisioning Parameters
CyberData Corporation
56
Need help?
Do you have a question about the 11304 and is the answer not in the manual?