Grid Director 4036/2036 Installation Manual
5. Install the switch by inserting the mount holders hooks into the dedicated rectangular slot
in the mount plates.

Figure 51: Inserting the mount holder into the mount plate

6. On the front side of the rack, secure the front of the chassis, aligning the mount brackets
holes with the rack holes of the correct U level.
Note: The Philips screws are not provided by Mellanox.
Figure 52: Securing the front of the chassis
7. Connect the power cords to the power supplie (PSU) at the front of the chassis (repeat for
the other power supply, if present).
8. At the rear of the chassis, connect the InfiniBand cables.