Suzuki GSX-R1000 Service Manual page 399

Hide thumbs Also See for GSX-R1000:
Table of Contents

Advertisement

ELECTRICAL SYSTEM
9-35
o
10
20
30
40
50
60
Time
(Minutes)
Charging period
..L __
Stop charging
~
1\
"""' "
(V)
18
17
16
15
14
13
12
* When recharging the battery, remove the battery
from the motorcycle.
* Do not remove the caps on the battery top while
recharging.
RECHARGING OPERATION
• Using the multi circuit tester, check the battery voltage. If the
voltage reading is less than the 12.0 V (DC), recharge the bat-
tery with a battery charger.
I
CAUTION
I
100
75
50
25
0
(%)
Battery charged condition
(at 0
0
_
40 'C)
"'-
~
~
~
-~
12
11
10
(V)
14
13
Be careful not to permit the charging current to
exceed 5 A at any time.
• After recharging, wait for more than 30 minutes and check the
battery voltage with a multi circuit tester.
• If the battery voltage is less than the 12.5 V, recharge the bat-
tery again.
• If battery voltage is still less than 12.5 V, after recharging,
replace the battery with a new one.
• When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.
Recharging time: 5 A for 1 hour or 1.2 A for 5 to 10 hours