Fan events (300 through 399)

Event code: 300
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan failed or is rotating at insufficient angular velocity.
Action:
Contact IBm to replace the power supply containing the indicated fan module.
Event data:
The first byte of event data (byte 0) specifies the failed fan number.
Distribution:
Product
EFCM Basic
Event Log
Event code: 301
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans failed or are rotating at insufficient angular velocity.
Action:
Contact IBm to replace the power supply containing the indicated fan module.
Event data:
The first byte of event data (byte 0) specifies the failed fan number(s).
Distribution:
Product
EFCM Basic
Event Log