Map 300 Error Messages - IBM TotalStorage SAN32M-2 Installation And Service Manual

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

112
SAN32M-2 Installation and Service Manual

MAP 300 error messages

Table 11
Error message
Never connected.
Link timeout.
Protocol mismatch.
Duplicate session.
Unknown network address.
Incorrect product type.
8
Transmit or receive errors for the Ethernet adapter exceeded a
threshold, the link was not connected, or the link timed out. A problem
with the Ethernet cable, Ethernet hub(s), or other LAN-attached
device is indicated. Verify the product is connected to the
management server through one or more Ethernet hubs:
a. Ensure an RJ-45 Ethernet cable connects the product to a hub.
If not, connect the cable as directed by the customer.
b. Ensure an RJ-45 Ethernet cable connects the management
server to a hub. If not, connect the cable as directed by the
customer.
c. Ensure Ethernet cables are not damaged. If damaged, replace
the cables.
Was the maintenance action successful?
NO
YES
The management server connection is restored. Exit MAP.
9
Does the configuration use multiple daisy-chained Ethernet hubs?
YES
NO
Go to
step
11.
Action
Go to
step
8.
Go to
step
8.
Go to
step
15.
Go to
step
18.
Go to
step
21.
Go to
step
23.

Advertisement

Table of Contents
loading

Table of Contents