Event code: 206
Message:
Power supply removed.
Severity:
Informational.
Explanation:
A power supply was removed while the switch was powered on and operational. The second power supply
assumes the full operating load.
Action:
No action required or install an operational power supply.
Event data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
Event code: 207
Message:
Power supply installed.
Severity:
Informational.
Explanation:
A redundant power supply was installed with the switch powered on and operational. Both power supplies adjust
to share operating load.
Action:
No action required.
Event data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log