Event code: 370
Message:
Cooling fan status polling temporarily disabled.
Severity:
Minor.
Explanation:
The failed or recovered status values for one or more cooling fans are exceeding a determined threshold. This
indicates a possible fan failure. Fan status polling is enabled hourly or following an IML or reset.
Action:
No immediate action required. Monitor cooling fan operation or additional event codes indicating a fan failure.
Event data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
246
SAN32M-2 Installation and Service Manual
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
Host
Link Incident
Log