IBM TotalStorage SAN32M-2 Installation And Service Manual page 282

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

Event code: 514
Message:
Optical transceiver failure.
Severity:
Major.
Explanation:
An optical transceiver failed. The amber LED corresponding to the port illuminates to indicate the failure. Ports
with LEDs extinguished remain operational.
Action:
Replace the failed transceiver.
Event data:
Byte 0 = port number.
Byte 1 = engineering reason code.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution:
Product
EFCM Basic
Event Log
Event code: 515
Message:
Optical digital diagnostics warning threshold exceeded.
Severity:
Minor.
Explanation:
An optical transceiver digital diagnostics warning threshold was exceeded. Additional event code 515 events are
recorded if the problem persists.
Action:
Replace the transceiver.
Event data:
Byte 0 = port number.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 31 = First, second, and third type (and threshold value) of warning threshold exceeded as follows:
01 = TX temperature, 02 = TX supply voltage, 03 = TX bias current, 04 = TX power, 05 = RX power.
Distribution:
Product
EFCM Basic
Event Log
256
SAN32M-2 Installation and Service Manual
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info
Host
Link Incident
Log
Host
Link Incident
Log

Advertisement

Table of Contents
loading

Table of Contents