Configure, enable, and test call-home event notification

1. Minimize the Element Manager application and return to the
SAN management application.
2. At the SANavigator or EFCM main window, select Ethernet Event
from the Monitor menu. The Configure Ethernet Events dialog box
displays.
3. Click the Enable Ethernet Events check box. A check mark appears
to indicate Ethernet events are enabled.
4. At the Ethernet Timeout field, type a value between 10 through 120
minutes.
5. Click OK to close the dialog box.
Telephone numbers and other information for the call-home feature
are configured through the Windows dial-up networking application.
Refer to
Task 10: Configure the call-home feature (optional)
configuration instructions. To configure, enable, and test call-home
event notification:
NOTE: The call-home feature may not be available if the EFCM Basic
application is installed on a customer-supplied platform.
1. Minimize the Element Manager application and return to the
SAN management application.
2. At the SANavigator or EFCM main window, select Event
Notification and Call Home from the Monitor menu. The Call Home
Event Notification Setup dialog box displays.
3. Click the Enable Call Home Event Notification check box. A check
mark appears to indicate call-home event notification is enabled.
NOTE: The enable function must be activated for each product through
the Element Manager application.
4. Click Send Test. A call-home test message is sent.
5. Click OK to close the dialog box.
6. Maximize the Element Manager application.
7. Select Enable Call Home Notification from the Maintenance menu at
any view. A check mark appears to indicate call-home event
notification is enabled.