Huawei IPC6521-Z20-FI 1080P User Manual page 65

1080p intelligent network speed dome
Table of Contents

Advertisement

IPC6521-Z20-FI 1080P Intelligent Network Speed
Dome
User Guide
Parameter
Alarm check interval
Step 5 Click Add and draw points on the live video image to form a sensitive area.
Step 6 Set Name.
Step 7 Click Save.
The removed object detection function is configured.
----End
Verification
When an individual removes an object from the sensitive area:
Issue 02 (2013-09-30)
To delete a sensitive area, select the sensitive area ID from the sensitive area list (only the selected
sensitive area is displayed in white on the live video image), click Delete.
A sensitive area can be a polygon of three vertices or more.
A sensitive area can have a maximum of 10 vertices.
A single behavior analysis function supports up to four sensitive areas. If all functions are enabled, a
maximum of 10 sensitive areas can be analyzed at a time.
You can perform operations on only one sensitive area at a time.
A maximum of 15 and 30 objects can be analyzed in close-up object and distant object modes
respectively.
When the resolution is set to 352 x 288, the system can analyze objects with a minimum size of 10 x
10, and a maximum size of 100 x 100 and 100 x 200 in distant object and close-up object modes
respectively. The values indicate limitations on the object area instead of the object's length or
height.
If the object is marked with a red box and its movement track is displayed as a red line
on the live video image, removed object detection is successfully configured.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
central part.
Bottom: indicates that an
object is identified via its
bottom part.
Top: indicates that an
object is identified via its
top part.
Time interval at which the
system checks for new
alarms. The system then
reports detected alarms to
the surveillance platform.
NOTE
To prevent a flood of alarms,
the system reports only one
alarm even if it detects
multiple alarms within the
specified interval.
5 Device Configuration
Setting
[Value range]
An integer ranging from 1 to
256
[Default value]
3
[Unit]
s
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipc6521-z20-fi

Table of Contents