Intel® Server Board SE7520JR2
5.3.5.4.2
Fault / Status LED
The following table shows mapping of sensors/faults to the LED state.
Color
Condition
Solid
Green
Blink
Solid
Amber
Blink
Off
Solid
Critical Condition - Any critical or non-recoverable threshold crossing associated with the
following events:
•
Temperature, voltage, or fan critical threshold crossing
•
Critical Event Logging errors, including System Memory Uncorrectable ECC errors and
FSB Bus errors,.
Non-Critical Condition
•
Temperature, voltage, or fan non-critical threshold crossing
•
Chassis intrusion
Degraded Condition
•
One or more processors are disabled by Fault Resilient Boot (FRB)
5.3.5.4.3
Chassis ID LED
The Chassis ID LED provides a visual indication of a system being serviced. The state of the
Chassis ID LED is toggled by the chassis ID button or it can be controlled by the Chassis
Identify command.
Color
Condition
Off
Blue
Blink
5.3.5.5
Control Panel Inputs
The mBMC monitors the control panel switches and other chassis signals. The control panel
input buttons are momentary contact switches, which are de-bounced by the mBMC processor
firmware. The de-bounce time is 25 ms.
Revision 1.0
Table 50: Fault / Status LED
System ready
System ready, but degraded: CPU disabled
Critical failure: critical fan, voltage, or temperature state
Non-critical failure: non-critical fan, voltage, or temperature state
System not ready: POST error / NMI event / CPU or terminator missing
Table 51: Chassis ID LED
Ok
Identify button pressed or Chassis Identify command executed
C78844-002
Platform Management
When
When
129