Platform Management
•
Combined power and reset button assertion
If DC power is off, an assertion of the PWBTIN while the RSTIN is asserted generates
an OEM-specific Control Panel event to PEF. The event attributes are: Sensor Type
code - 14h (Button) and Sensor Specific offset - 07h. This PEF action initiates a BIOS
CMOS clear request to the system BIOS.
The user interface of the control panel consists of the following indicators:
•
Power LED
•
Fault/Status LED
•
Chassis ID LED
For user input, the standard control panel can provide the following buttons/switches:
•
Reset button
•
Power button
•
NMI/SDI button
•
Chassis ID button
•
Chassis intrusion switch (optional)
5.3.5.4
Control Panel Indicators
The mBMC is capable of supporting three control panel indicators: Power LED, Fault/Status
LED, and Chassis ID LED. The states of these indicators and how they relate to the
mBMC/chassis state are detailed below.
5.3.5.4.1
Power LED
The BIOS controls the control panel Power LED as described in the table below.
State
Power Mode
Power Off
Non-ACPI
Power On
Non-ACPI
128
Table 49: SSI Power LED Operation
LED
OFF
System power is off, and the BIOS has not initialized the chipset.
ON
System power is on, but the BIOS has not yet initialized the chipset.
C78844-002
Intel® Server Board SE7520JR2
Description