Connectors and Jumper Blocks
FMC Signal Name
LAN_I2C_3VSB_SCL
HDD_FLT_LED_N
FMM_PS_PWR_ON_N
COOL_FLT_LED_N
FMM_CPU_VRD_EN
FMM_SCI_N
ICH_PWR_BTN_N
FMM_SPKR_N
FP_NMI_BTN_N
FP_SLP_BTN_N
FP_ID_BTN_N
SYS_PWR_GD
CPU2_SKTOCC_N
CLK_32K_RTC
CPU1_SKTOCC_N
FMM_SOUT
FMM_SIN
FMM_DCD_N
FMM_RTS_N
FMM_DTR_N
FMM_CTS_N
ICMB_RX
ICMB_TX
ICMB_TX_EN
186
FMC
Pin
58
LAN usage
64
Drive Fault LED output driven when FMM detects a bad drive from the Hot
Swap controller on the Hot Swap disk Drive sub-system.
65
Power On Request to the system Power Supply
66
Cool Fault LED output driven when FMM detects a bad Fan if SSI front panel is
detect.
67
This signal is driven by the FMM to enable the CPU VRDs and allow the VRD
power good chain to complete. This signal can also be used to keep the system
in reset for an extended time, beyond what the chipset RST_BTN_N can
provide.
68
SCI event request. If ACPI EC is supported by FMM, this signal is used for ACPI
interrupts.
69
FMM pass through of Front panel power button to chipset
72
FMM uses this to create Beep Codes on the system audible alarm. This signal is
configured as an Open Drain buffer in the FMM and must be pulled up to 3.3V
Standby on the motherboard
73
NMI / Diagnostic interrupt from front panel. Actual NMI generated by SMBUS
command to mBMC
74
Front panel Sleep Button input, if used
75
Front panel ID button, will cause the ID light to toggle
76
Signal from the end of the baseboard VRD Power good chain. This signal
should be the last VRD power good indication generated on the baseboard.
Usually this would be the signal feeding the Chipset Power OK input. Used by
FMM in conjunction with RST_PWRGD_PS to determine if all critical VRDs
have successfully reached their nominal value.
80
Indicates that a Processor is in the application processor socket
81
This signal is used for "Synchronized clock with system RTC". FMM can
synchronize own RTC with system RTC. IPMI define synchronized method.
clock comes from the Chipset RTC function.
82
Indicates that a Processor is in the primary processor socket. If this socket is
detected empty and there's an attempt to power up the system, the FMM will
output an Error Beep Code and prevent the System from turning on
85
EMP/SOL Serial Data Out. This is the Serial Port data output from FMM and
should be connected to the SIN signal in the SIO3 device
86
EMP/SOL Serial Data In. This is the Serial Port data input into the FMM and
should be connected to the SOUT signal in the SIO3 device
87
EMP/SOL Data Carrier Detect. This is the Serial Port Data Carrier Detect input
into the FMM and should be connected to the DCD signal in the SIO3 device
88
EMP/SOL Request to Send. This is the Serial Port Request to Send output from
FMM and should be connected to the CTS (Clear to Send) signal in the SIO3
device
89
EMP/SOL Data Terminal Ready. This is the Serial Port Data Terminal Ready
output from FMM and should be connected to the DSR (Data Set Ready) signal
in the SIO3 device
90
EMP/SOL Clear to Send. This is the Serial Port Clear to Send input into the
FMM and should be connected to the RTS (Ready to Send) signal in the SIO
device
93
Inter Chassis Communication Management Bus receive data
94
Inter Chassis Communication Management Bus transmit data
96
Inter Chassis Communication Management Bus transceiver enable