Table 62: Virus Related Bios Messages; Table 63: System Configuration Bios Messages - Intel SE7520JR2 Technical Manual

Server board technical product specification
Table of Contents

Advertisement

Error Reporting and Handling
Message Displayed
Message Displayed
BootSector Write !!
VIRUS: Continue (Y/N)?
Message Displayed
DMA-2 Error
DMA Controller Error
Checking NVRAM..Update Failed
Microcode Error
NVRAM Checksum Bad, NVRAM Cleared
Resource Conflict
NVRAM Ignored
NVRAM Bad
Static Resource Conflict
PCI I/O conflict
PCI ROM conflict
PCI IRQ conflict
PCI IRQ routing table error
Timer Error
160

Table 62: Virus Related BIOS Messages

Table 63: System Configuration BIOS Messages

C78844-002
Intel® Server Board SE7520JR2
Description
when it detects an imminent failure.
This message can be reported by an ATAPI device using
the S.M.A.R.T. error reporting standard. S.M.A.R.T.
failure messages may indicate the need to replace the
hard disk.
Description
The BIOS has detected software attempting to write to a
drive's boot sector. This is flagged as possible virus
activity. This message will only be displayed if Virus
Detection is enabled in AMIBIOS setup.
If the BIOS detects possible virus activity, it will prompt
the user. This message will only be displayed if Virus
Detection is enabled in AMIBIOS setup.
Description
Error initializing secondary DMA controller. This is a fatal
error, often indication a problem with system hardware.
POST error while trying to initialize the DMA controller.
This is a fatal error, often indication a problem with
system hardware.
BIOS could not write to the NVRAM block. This message
appears when the FLASH part is write-protected or if
there is no FLASH part (System uses a PROM or
EPROM).
BIOS could not find or load the CPU Microcode Update
to the CPU. This message only applies to INTEL CPUs.
The message is most likely to appear when a brand new
CPU is installed in a motherboard with an outdated
BIOS. In this case, the BIOS must be updated to include
the Microcode Update for the new CPU.
There was an error in while validating the NVRAM data.
This causes POST to clear the NVRAM data.
More than one system device is trying to use the same
non-shareable resources (Memory or I/O).
The NVRAM data used to store Plug'n'Play (PnP) data
was not used for system configuration in POST.
The NVRAM data used to store Plug'n'Play (PnP) data
was not used for system configuration in POST due to a
data error.
Two or more Static Devices are trying to use the same
resource space (usually Memory or I/O).
A PCI adapter generated an I/O resource conflict when
configured by BIOS POST.
A PCI adapter generated an I/O resource conflict when
configured by BIOS POST.
A PCI adapter generated an I/O resource conflict when
configured by BIOS POST.
BIOS POST (DIM code) found a PCI device in the
system but was unable to figure out how to route an IRQ
to the device. Usually this error is causing by an
incomplete description of the PCI Interrupt Routing of the
system.
Indicates an error while programming the count register
Revision 1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se7520jr2atad2