Error Reporting and Handling
Tpoint
0E5h
0E6h
0E8h
0E9h
0EAh
0EBh
0ECh
0EDh
0EEh
0EFh
0F0h
0F1h
0F2h
0F3h
0F4h
6.6
Light Guided Diagnostics
The baseboard provides system fault/status LEDs in many areas of the board. There are fault
LEDs for each DIMM slot and for each processor, and status LEDs for 5-volt stand-by and
system state. Operation of some of these LEDs is dependant upon whether an IMM is installed
or not. With on-board platform instrumentation, there is limited diagnostic LED support.
•
In systems configured with an IMM, the CPU 1 or CPU 2 led is lit to indicate the processor
is disabled. DC-Off or AC Cycle will cause the LED to turn off.
•
CPU 1 and 2 LEDs are both lit to indicate the baseboard HW has discovered a
configuration error. If processor mis-population is detected when using standard on-board
platform instrumentation, baseboard hardware will illuminate both processor error LEDs. If
an IMM (Professional or Advanced editions) is used, the Sahalee BMC will generate a
series of beep codes when this condition is detected and will illuminate the processor 1
fault LED. An AC cycle will cause the LEDs to turn off.
•
DIMM fault LEDs are lit by BIOS whenever BIOS disables a specific DIMM.
•
The 5-Volt stand-by LED is always lit when 5-volt stand-by is present.
•
The Status LED displays the state of the system. It mirrors the state of the Control Panel
Status LED. Valid states include: Solid Green, Blinking Green, Blinking Amber, Solid
Amber, and Off.
174
Description
MEM_ERR_SIZE_MISMATCH
MEM_ERR_ECC_MISMATCH
MEM_ERR_ROW_ADDR_BITS
MEM_ERR_INTERNAL_BANKS
MEM_ERR_TIMING
MEM_ERR_INST_ORDER_ERR
MEM_ERR_NONREG_MIX
MEM_ERR_LATENCY
MEM_ERR_NOT_SUPPORTED
MEM_ERR_CONFIG_NOT_SUPPORTED
SYS_FREQ_ERR
(Flag for Unsupported System Bus Freq)
DIMM_ERR_CFG_MIX
(Usupported DIMM mix)
DQS_FAILURE
(indicates DQS failure)
MEM_ERR_MEM_TEST_FAILURE
(Error code for unsuccessful Memory Test)
MEM_ERR_ECC_INIT_FAILURE
(Error code for unsuccessful ECC and Memory Initialization)
C78844-002
Intel® Server Board SE7520JR2
Revision 1.0