Agp Routing Ground Reference; Figure 45. Agp Decoupling Capacitor Placement Example - Intel 815 Design Manual

Chipset platform for use with universal socket 370
Table of Contents

Advertisement

R

Figure 45. AGP Decoupling Capacitor Placement Example

This figure is for example purposes only. It does not necessarily represent complete and correct
NOTE:
routing for this interface.
7.3.6

AGP Routing Ground Reference

It is strongly recommended that, at a minimum, the following critical signals be referenced to
ground from the GMCH to an AGP connector (or to an AGP video controller if implemented as a
"down" solution on an AGP-only motherboard), using a minimum number of vias on each net:
AD_STB0, AD_STB0#, AD_STB1, AD_STB1#, SB_STB, SB_STB#, G_GTRY#, G_IRDY#,
G_GNT#, and ST[2:0].
In addition to the minimum signal set listed previously, it is strongly recommended that half of all
AGP signals be reference to ground, depending on board layout. In an ideal design, the entire AGP
interface signal field would be referenced to ground. This recommendation is not specific to any
particular PCB stack-up, but should be applied to all designs using the Intel 815 chipset platform
for use with the universal socket 370.
®
Intel
815 Chipset Platform Design Guide
AGP/Display Cache Design Guidelines
AGP_decoupling_cap_placement
89

Advertisement

Table of Contents
loading