Removing FB-DIMMs
FIGURE 4-4
7. Place the FB-DIMM on an antistatic mat.
8. Repeat
4.1.4
Installing FB-DIMMs
Caution – Ensure that all power is removed from the server before removing or
installing FB-DIMMs, or damage to the FB-DIMMs might occur. You must disconnect
all power cables from the system before performing this procedure.
Tip – See
configuring the FB-DIMMs.
1. Unpackage the replacement FB-DIMMs and place them on an antistatic mat.
2. Ensure that the ejector tabs are in the open position.
3. Line up the replacement FB-DIMM with the connector (
Align the FB-DIMM notch with the key in the connector. This ensures that the
FB-DIMM is oriented correctly.
4-8
Sun Fire X4450 Server Service Manual • November 2009
Step 5
through
Step 7
Section 4.1.2, "FB-DIMM Guidelines" on page 4-4
to remove any additional FB-DIMMs.
for information about
).
FIGURE 4-5