6. Install the top cover.
See
7. Install the server into the rack.
See
8. Install the drives.
Note – Ensure you are installing the drives in the correct drive bays.
See
9. Install the DVD/USB module.
See
10. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
11. Power on the server.
See
5.3
Servicing the Drives Backplane
You must remove the drives backplane to service the front control panel light pipe
assemblies.
Note – FRU: This field-replaceable unit should be replaced only by qualified service
technicians. Contact your Sun Service representative for assistance.
5.3.1
Removing the Drives Backplane
1. Remove the drives cage.
See
2. Remove the four No. 2 Phillips screws securing the backplane to the drives
cage. (
5-8
Sun Fire X4450 Server Service Manual • November 2009
Section 6.1, "Installing the Top Cover" on page
Section 6.2, "Reinstalling the Server in the Rack" on page
Section 3.2.5, "Installing a Hard Drive or SSD" on page
Section 3.5.2, "Installing the DVD/USB Module" on page
Section 6.4, "Powering On the Server" on page
Section 6.4, "Powering On the Server" on page
Section 5.2.1, "Removing the Drives Cage" on page
)
FIGURE 5-5
6-2.
6-3.
3-7.
3-22.
6-5.
6-5.
5-5.