Sun Microsystems Sun Fire X4450 Service Manual page 84

For 2u systems
Hide thumbs Also See for Sun Fire X4450:
Table of Contents

Advertisement

4. Remove the PCIe riser board.
See
5. Remove the PCI filler panel.
PCIe filler panels are located in the motherboard back panel.
6. Insert the PCIe card into the correct slot on the riser board. (
7. Replace the riser board.
a. Slide the riser back until it seats in its slot in the back panel.
b. Tighten the captive No. 2 Phillips screw securing the riser to the
8. Install the top cover.
See
9. Slide the server into the rack.
See
10. Connect any data cables required to the PCIe card.
Route data cables through the cable management arm.
11. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
12. Power on the server.
See
4-26
Sun Fire X4450 Server Service Manual • November 2009
Section 4.5, "Servicing PCIe Risers" on page
motherboard.
Section 6.1, "Installing the Top Cover" on page
Section 6.3, "Returning the Server to the Normal Rack Position" on page
Section 6.4, "Powering On the Server" on page
Section 6.4, "Powering On the Server" on page