Caution – The drive data cables are delicate. Carefully connect them and make sure
that they are seated properly when servicing the motherboard.
10. Reinstall the memory tray.
See
Section 4.2.2, "Installing the Memory Tray" on page
11. Loosen the captive retaining screw that holds the front end of the riser to the
motherboard.
Be careful when routing the drive cables so they don't get pinched and are
underneath the ribs on the support.
12. Reinstall the PCIe cards and risers.
See
Section 4.5.2, "Installing a PCIe Riser" on page
13. Reinstall the top cover.
See
Section 6.1, "Installing the Top Cover" on page
14. Reinstall the server into the rack.
See
Section 6.2, "Reinstalling the Server in the Rack" on page
15. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, "Powering On the Server" on page
16. Power on the server.
See
Section 6.4, "Powering On the Server" on page
4-13.