13. After a successful flash, remove the AC power.
See
Section 2.4, "Powering Off the Server" on page
14. Remove the jumper.
15. Remove the flash drive from the USB port.
16. Replace PCI cards from Riser 1.
See
Section 4.6.3, "Installing a PCIe Card" on page
17. Reinstall the top cover.
See
Section 6.1, "Installing the Top Cover" on page
18. Slide the server into the rack.
See
Section 6.3, "Returning the Server to the Normal Rack Position" on page
19. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, "Powering On the Server" on page
20. Power on the server.
See
Section 6.4, "Powering On the Server" on page
21. Start the BIOS.
22. Confirm that the SP is listed in the BIOS settings under Server/AST2000 LAN
Configuration.
23. Exit the BIOS and start the operating system.