10. Remove the jumper from position 1-3, and replace it in its original location.
11. Install the top cover.
See
12. Slide the server into the rack.
See
13. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
14. Power on the server.
See
NVRAM is cleared.
4.11
Recovering from Corrupt Service
Processor Software
If the SP (service processor) software becomes corrupted, you can reinstall the default
SP software image from the Tools and Drivers CD.
You need:
The Tools and Drivers CD.
A bootable USB flash device.
A jumper cap. The server has a jumper cap installed on the motherboard, next to
the AST 2000 chip.
4.11.1

Recovering from Corrupt SP Software

1. Copy the following SP files from the Tools and Drivers CD, located in the
BMCrecovery directory, to a USB flash device.
2. Remove AC power from the server to be flashed.
See
4-46
Sun Fire X4450 Server Service Manual • November 2009
Section 6.1, "Installing the Top Cover" on page
Section 6.3, "Returning the Server to the Normal Rack Position" on page
Section 6.4, "Powering On the Server" on page
Section 6.4, "Powering On the Server" on page
SOCFLASH.EXE
DOS4GW
BMC Binary (The SP Binary file)
Section 2.4, "Powering Off the Server" on page
6-2.
6-5.
6-5.
2-3.
6-4.