Advertisement

Note – Make a note of the drive locations before removing them from the system.
You will need to install the drives in the correct locations when reassembling the
system.
7. If you are servicing the drives backplane, remove the DVD/USB module.
See
8. Remove the fan modules.
See
9. Remove the No. 2 Phillips screws securing the drives cage to the chassis. (
and [2])
Two screws secure the drives cage to each side of the chassis.
10. Slide the drives cage forward to disengage the backplane from the paddle card.
(
FIGURE 5-3
11. Lift the drives cage up and disconnect the drive data cables. (
Press the connector release button to release the cable.
12. Set the drives cage on an antistatic mat.
FIGURE 5-3
5-6
Sun Fire X4450 Server Service Manual • November 2009
Section 3.5.1, "Removing the DVD/USB Module" on page
Section 3.3.4, "Removing a Fan Module" on page
[3])
Removing the Drives Cage
3-21.
3-12.
[4])
FIGURE 5-3