Figure 24-29 Pbook -Print Commend - Dynamix DW1-FXS User Manual

Fxs gateway (h..323)
Table of Contents

Advertisement

--port: Call signal port number of caller
--drop : Drop e.164 number when dial out. 0 means to keep e.164 number, 1 means to
drop e.164 number when dialing out.
--inert: Insert digits.(1~10 digits)
usr/config$ pbook –add name test e164 100 ip 192.168.13.78
-modify: modify an existing record. When using this command, users have to specify the
record's index number, and then make the change.
usr/config$ pbook –modify 1 name test e164 5678 ip 192.168.1.10 port 1730 drop 0
-delete: delete a specific record. [pbook –delete 3] means delete index 3 record.
usr/config$ pbook –delete 3
PhoneBook Rules:
The e164 number defined in phone book will fully carry to destination. It is not just a
representative number for destination's IP Address. In other words, user dial this e164 number to
reach destination, destination will receive the number and find out if it is matched to its e164,
including Line number in some particular device.
For example:
usr/config$ pbook –print
Phone book information and configuration
Index Name
========================================================
1
test
usr/config$
24.7.14
[voice]
The voice command is associated with the audio setting information. There are four voice
codecs supported by Gateway.
usr/config$ voice
Voice codec setting information and configuration
Usage:
voice [-print]
[-send [G723 ms] [G729 ms] [G729A ms] [G729B ms] [G729AB ms] [G711U ms]
[G
FXS H.323 VoIP Gateway User Manual
E.164
IP
100
192.168.13.78

Figure 24-29 pbook -print commend

Port Drop
Insert
1720 Disable
- 112 -