Framing; Installation Planning - kozy heat CALLAWAY 40 Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

3.0 FRAMING

3.1 Installation Planning

This appliance offers several design options for managing the heat
produced by this fireplace.
Read all documentation for your specific installation
and design options prior to appliance installation.
Standard Installation will be outlined in this manual in sections
marked 'standard installation' and must be followed if no
design options (vented cavity and Komfort Zone Kit) are to be
used. If planning a standard installation with the use of a heat
transfer kit(s) (HTK-EXT and/or HTK-INT), the standard framing
dimensions will still apply.
Heat Transfer Kit(s) allows you to transfer heat to a specific area
inside your home (interior) or directly outside (exterior). This
appliance can have (2) heat transfer kits installed at the same
time. It can be up to two of the same heat transfer kits, or a
combination of interior and exterior kits. See the HTK-EXT and/
or HTK-INT manuals for further information.
If you are planning a standard installation with the use of an
exterior and/or interior kit, the minimum dimensions listed in
this section will apply for your framing installation. You will still
need to remove the cover plates as instructed in section 3.7.1 on
page 19. If you are installing a heat transfer kit with the use
of a KZK or vented cavity option, the minimum requirements
applicable to those options must be adhered to.
Vented Cavity offers the option to leave a minimum sized
opening in the fireplace cavity, allowing for heat reduction above
the fireplace. This option allows for combustible facing materials
above the fireplace, heat reduction for a TV mounted above the
fireplace, and lower mantel clearances.
Cavity and Komfort Zone Kits on page 20.
All vented cavity options have different minimum chamber and
ceiling dimension requirements when compared to the standard
installation dimensions in this section. The fireplace chamber
and ceiling minimum height must be 74" (1880mm) for all
vented cavity options.
Reference Section 3.7.2 Vented Cavity
and Komfort Zone Kits on page 20.
Komfort Zone Kit offers the option to redistribute radiant heat
through plenum(s).
This option allows for combustible facing
materials above the fireplace, heat reduction for a TV above the
fireplace, and lower mantel
Cavity and Komfort Zone Kits on page 20.
If installing a Komfort Zone Kit (#KZK-044 or #KZK-158A),
the framing requirements may be different than the standard
dimensions listed in this section. Please reference the manual
included with your kit before completing all fireplace framing
and other installation considerations.
Kozy Power Vent is a fan-powered mechanical draft vent system
(horizontal terminations only) for use with any of the design
options listed in this section. To convert the fireplace for use
with Kozy Power Vent, order the #KPV kit and the #KPV control
module #700-759 (sold separately from kit).
It is easier to convert the fireplace for use with the #KPV before
framing in the fireplace. If you convert the fireplace for use with
the #KPV after fireplace installation, you will have to access the
control board assembly for the #KPV installation.
See Section 8.3 Control Board Removal and Installation on page
53 for access to the control board before and after installation.
Refer to the Kozy Power Vent manual for more information.
#CLW-40 R.3 November 2021
See Section 3.7.2 Vented
clearances. See Section 3.7.2 Vented
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
If planning to convert to propane, it is easier to complete the gas
conversion before framing in the fireplace. See the #LCK-CW40-
SPB manual for complete conversion instructions. If you convert
the fireplace to propane after fireplace installation, you will have
to remove the control board. See Section 8.3 Control Board
Removal and Installation on page 53 for access to the control
board before and after installation.
Please read the instructions in this manual carefully for your
specific installation.
3.1.1 Appliance Placement Considerations
WARNING: Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
This appliance must be installed on a level surface capable of
supporting the fireplace and venting. Determine your vent
requirements before framing your appliance.
If installing #KPV Kozy Power Vent, please reference the manual
included with the kit.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will
produce when determining a location.
3.1.2 Moving the Appliance
This appliance is heavy. We recommend a team lift when moving,
placing, and positioning the appliance.
On both sides of the appliance, there are lift handles that allow a
hand lift (no sharp edges), or allow a 2" x 4" piece of lumber to be
inserted inside the lift handles, as shown in Figure 3.1.
Figure 3.1, Lift Handles
2" x 4"
Lift handle
FRAMING 11