HP AlphaServer TS15 Owner's Manual page 201

Servers
Table of Contents

Advertisement

Alert Pending: NO
Latest Alert: AC Loss
Init String: AT&H2E0&C1&D0S0=2
Dial String: ATD915085554444
Alert String: ,,,,,,,,,,5551234
User String:
Com1 Baud:9600
Rmc:ENABLED
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK
Warning Threshold:
65.00°C
Fan Status: OK
PCI Riser: Installed
POST DPR: OK
RMC>
The following sequence explains the preceding example.
Sets the password that is prompted for at the beginning of a modem session. The
string cannot exceed 14 characters and is not case sensitive. For security, the
password is not echoed on the screen. When prompted for verification, type the
password again.
Sets the initialization string. The string is limited to 31 characters and can be
modified depending on the type of modem used. Because the modem commands
disallow mixed cases, the RMC automatically converts all alphabetic characters
entered in the init string to uppercase.
Clears the current alert.
Tells the RMC not to append its own fixed flow-control and carrier-detect
commands to the user-supplied modem initialization string. Instead, these will be
included as part of the user-supplied initialization string.
Enables remote access to the RMC modem port by configuring the modem with the
setting stored in the initialization string once the modem is connected to the system.
Status of the RMC configuration.
NOTE:
Once the RMC is configured, disconnect the VT terminal from COM1 (if present)
and connect the modem.
Flow:SOFTWARE
Mode:THROUGH
Thermal Shutdown: Enabled
60.00°C
Fan Shutdown: Enabled
NVRAM: OK
GPIOs: OK
Using the Remote Management Console
Modem:DISABLED
Fatal/Power-Down Threshold:
LM75: OK
6-23

Advertisement

Table of Contents
loading

Table of Contents