Troubleshooting
Using Logging To Identify Problem Sources
For example, on a switch where there are no SyslogD servers configured, you
would do the following to configure SyslogD servers 18.120.38.155 and
18.120.43.125 and automatically enable Syslog logging (with user as the default
logging facility):
logging < syslog-ip-addr
> configures the Syslog
server(s) to use and
enables Syslog debug
logging. (In this case,
Syslog is automatically
enabled because debug
destination logging has
not been previously
disabled with other Syslog
servers already
configured in the switch.
(Refer to the Syntax box
under "Configuring the
Switch To Send Debug
Messages to One or More
SyslogD Servers" on page
C-27.)
Figure C-9. Example of Configuring and Enabling Syslog Logging
To use a non-default logging facility, such as lpr, in the same operation as in
figure C-9, you would use this command set:
ProCurve(config)# logging 18.120.38.155
ProCurve(config)# logging 18.120.43.125
ProCurve(config)# logging facility lpr
C-28
ProCurve(config)# logging 18.120.38.155
ProCurve(config)# logging 18.120.43.125
ProCurve(config)# write mem
ProCurve(config)# show config
Startup configuration:
; J9085A Configuration Editor; Created on release #R.11.XX
hostname "ProCurve Switch 2610-24"
ip default-gateway 10.0.8.1
logging 18.20.38.155
logging 18.129.43.125
snmp-server community "public" Unrestricted
vlan 1
name "DEFAULT_VLAN"
untagged 1-28
ip address dhcp-bootp
exit
ProCurve(config)# show debug
Debug Logging
Destination:
Logging - -
18.120.38.155
18.120.43.125
Facility = user
Enabled debug types:
event
The configured Syslog server
IP addresses appear in the
switch's configuration file.
This command shows that
Syslog logging is enabled for
the listed IP addresses.