HP -UX B6941-90001 Administrator's Reference Manual page 252

Management server on hp-ux
Table of Contents

Advertisement

Table 5-31
Object
cpu_util
disk_util
Inetd
MailQueue
Length
proc_util
sco_tmp
sendmail
swap_util
a. Digital UNIX = 90%: No AIX or HP-UX 10.x
b. Digital UNIX = 10 mins: No AIX or HP-UX 10.x,
c. No SCO OpenServer or SINIX
d. No Digital UNIX
e. No Digital UNIX
f. SCO OpenServer only
g. SCO OpenServer only
h. No SCO OpenServer or SINIX
NOTE
Configuring ITO
Preconfigured Elements
Object Thresholds on the Managed Nodes
Description
Monitors CPU utilization: requires the
sar program
Monitors disk space utilization on the root
disk
Number of executing instances of inetd
(Internet Daemon)
Length of the sendmail queue: number of
unsent mail messages
Monitors process table utilization
Size in disk blocks of the ITO /tmp
directory on a SCO OpenServer managed
node
Number of executing instances of
sendmail
Monitors SWAP utilization. In the case of
HP-UX, versions 8.07 or higher only
No preconfigured monitors are available for Novell NetWare managed
nodes.
252
Polling
Threshold
Interval
(mins)
a
b
95%
2
90%
10
0.5
5
c
30
2
d
e
75%
5
f
1000
60
h
0.5
5
80%
5
Chapter 5
g

Advertisement

Table of Contents
loading