Parameter
Function name
No.
F002
Acceleration time 1
*
2nd acceleration
F202
time 1
F003
Deceleration time 1
*
2nd deceleration
F203
time 1
Operator rotation
F004
direction selection
*2nd control is displayed when '08 (2nd control)' is allocated to one of multi-function inputs from C001 to C006.
Monitor or data range
(Digital Operator)
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
00: Forward
01: Reverse
3-7 Parameter List
Changes
Default
during
Unit
setting
operation
10.0
Yes
s
10.0
Yes
s
10.0
Yes
s
10.0
Yes
s
00
No
Page
4-5
4-5
3
4-5
4-5
4-6
3-20