4-2 Function Mode
4
•To display and set each parameter for the 2nd control (200s of function codes), allocate SET and
SP-SET.
•Parameters changeable during operation are as follows:
Parameter No.
F002/F202
F003/F203
A001/A201
A002/A202
A003/A203
A004/A204
A020/A220
A042/A242
A043/A243
A044/A244
A045/A245
A046/A246
A047/A247
A061/A261
A062/A262
A092/A292
A093/A293
A094/A294
A095/A295
A096/A296
b012/b212
b013/b213
b021/b221
4-45
U/T1
V/T2
W/T3
Inverter
SET
/SP-SET
L
Function name
Acceleration time 1
Deceleration time 1
Frequency reference selection
RUN command selection
Base frequency
Maximum frequency
Multi-step speed reference 0
Manual torque boost voltage
Manual torque boost frequency
V/f characteristics selection
Output voltage gain
Automatic torque boost voltage compensation gain
Automatic torque boost slip compensation gain
Frequency upper limit
Frequency lower limit
Acceleration time 2
Deceleration time 2
2-step acceleration/deceleration selection
2-step acceleration frequency
2-step deceleration frequency
Electronic thermal level
Electronic thermal characteristics selection
Overload limit selection
Motor
1
Motor
2
Selection
SET
SP-SET
Yes
Yes
No
No
No
No
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes