Appendix-1 Parameter List
Parameter
Function name
No.
A071
PID selection
A072
PID P gain
A073
PID I gain
A074
PID D gain
A075
PID scale
PID feedback
A076
selection
Reverse PID
A077
function
PID output limit
A078
function
A081
AVR selection
AVR voltage
A082
selection
*2nd control is displayed when '08 (2nd control)' is allocated to one of multi-function inputs from C001 to C006.
App-7
Monitor or data range
(Digital Operator)
00: Disabled
01: Enabled
0.2 to 5.0
0.0 to 150.0
0.00 to 100.0
0.01 to 99.99
00: FI
01: FV
02: RS485 communication
10: Operation function output
00: OFF (Deviation = Target value - Feedback
value)
01: ON (Deviation = Feedback value - Target
value)
0.00 to 100.0
00: Always ON
01: Always OFF
02: OFF during deceleration
200-V class: 200/215/220/230/240
400-V class: 380/400/415/440/460/480
Changes
Default
during
Unit
setting
value
operation
00
No
1.0
Yes
1.0
Yes
s
0.0
Yes
s
1.00
No
Time
00
No
00
No
0.0
No
%
02
No
200/
No
V
400
Set