Register Number List
R/W in the list shows whether the coil or holding register accepts reading and/or writing.
R: Read only
Coil Number List
Coil No.
Function name
0000h
No used
0001h
RUN command
Rotation direction
0002h
command
0003h
External trip (EXT)
0004h
Trip reset (RS)
0005h
No used
0006h
No used
0007h
Multi-function input 1
0008h
Multi-function input 2
0009h
Multi-function input 3
000Ah
Multi-function input 4
000Bh
Multi-function input 5
000Ch
Multi-function input 6
000Dh
Not used
000Eh
Operation status
000Fh
Rotation direction
0010h
Inverter ready
0011h to 0013h Not used
0014h
Alarm signal
Excessive PID deviation
0015h
signal
0016h
Overload warning signal
*1. When either the control circuit terminal block or the coil is turned ON, these settings are ON.
The control circuit terminal block has the priority for the multi-function input terminals.
If the master cannot reset the coil ON status because of communication disconnection, turn the control
circuit terminal block from ON to OFF in order to turn off the coil.
*2. The content of a communications error is retained until a fault reset is input. (Can be reset during operation.)
R/W: Read and write enabled
R/W
1: RUN
R/W
0: Stop (Enabled when A002 = 03)
1: Reverse
R/W
0: Forward (Enabled when A002 = 03)
R/W
1: Trip
R/W
1: Reset
1: ON
R/W
0: OFF
1: ON
R/W
0: OFF
1: ON
R/W
0: OFF
1: ON
R/W
0: OFF
1: ON
R/W
0: OFF
1: ON
R/W
0: OFF
1: RUN
R
0: Stop (Interlocked with d003)
1: Reverse
R
0: Forward (Interlocked with d003)
1: Ready
R
0: Not ready
1: During trip
R
0: Normal
1: ON
R
0: OFF
1: ON
R
0: OFF
4-2 Function Mode
Description
*1
*1
*1
*1
*1
*1
4
4-76