2-2 Removing and Mounting Each Part
Mounting the Control Circuit Terminal Blocks
Step (1)
Push control circuit terminal block A (Terminals SC, S1 to S6) down securely on the Inverter's front
(upper direction in the figure on the previous page).
2
Step (2)
Push control circuit terminal block B (Terminals FS, FV, FI, FC, AM, PC, P2, P1) down securely from
the Inverter's bottom (right lower direction in the figure on the previous page). Furthermore, securely
tighten the screws on the both sides of the terminal block. Loosened screws may result in the ter-
minal block falling off.
Note: To remove/mount the control circuit terminal blocks, you need a screwdriver with a tip size of
2-9
+No.0, and a shaft diameter of 2.4 mm or less.