Installation Environment
•Increased ambient temperatures will shorten the life of the Inverter.
•Keep the Inverter away from heating elements (such as a braking resistor, DC reactor, etc.).
If the Inverter is installed in a control panel, keep the ambient temperature within the range of the
specifications, taking dimensions and ventilation into consideration.
5 cm min.
•If the ambient temperature is from 40°C to 50°C, the carrier frequency should be reduced and the Inverter
capacity should be increased.
•Before installing the Inverter, place a cover over all the ventilation openings to shield them from foreign
objects.
After completing the installation process, be sure to remove the covers from the Inverter before operation.
Relay output
terminal block
10 cm min.
5 cm min.
10 cm min.
Top cover
Control circuit
terminal block A
Control circuit
terminal block B
Main circuit
terminal block
2-1 Installation
Airflow
Wall
2-4