Excessive PID Deviation Output
This function outputs a signal when the deviation has exceeded the set value during the use of the
PID function.
Data
Symbol
04
OD
Available input terminals
Required settings
Parameter No.
C044
PID deviation excessive level
•C044 can be set from 0 to 100. The setting corresponds to the range of 0 to the maximum target
value.
C041
C041

Alarm Output

This is output when the Inverter trips. If you use the relay for alarm outputs, set and check operation,
as the SPDT contact is used for the terminals. For details, refer to the description of the relay output,
"Multi-function Output Terminal ON Delay/OFF Delay" (page 4-60).
Function name
Excessive PID deviation
P1-PC, P2-PC, MA-MC (or MB-MC)
Function name
0.0 to 100.0
OD
ON
Operation
Error
Trip
Status
The PID deviation has exceeded the C044 set
ON
value.
The PID deviation has not reached the C044 set
OFF
value.
C021, C026, C044
Data
Feedback value
Target value
ON
STOP
RESET
RUN
Stop
STOP
RESET
Error
Alarm output
4-2 Function Mode
Description
Default setting
Unit
30.
%
4-56
4