4-2 Function Mode
Register
Function name
No.
00D3h
Not used
00D4h
Not used
00D5h
Not used
00D6h
Not used
00D7h
Not used
00D8h
Not used
00D9h
Motor capacity selection
4
2nd motor capacity
00DAh
selection
Motor pole number
00DBh
selection
2nd motor pole number
00DCh
selection
00DDh
Stabilization parameter
00DEh
2nd stabilization parameter
*1. The Inverter's rated current is "1000".
*2. The second decimal place is ignored when the value is over 10000 (100.0 seconds).
Register
Function name
No.
0100h
0101h
0102h
0103h
Fault monitor 1
0104h
0105h
0106h
0107h
0108h
0109h
010Ah
010Bh
Fault monitor 2
010Ch
010Dh
010Eh
010Fh
* Stores the value changed by the communication. For details, refer to "To Save the Change to the Holding
Register (Enter Command)" (page 4-75).
4-87
Parameter
R/W
No.
function
H003
R/W
00: 0.2/02: 0.4/04: 0.75/06: 1.5/07: 2.2/
09: 3.7/11: 5.5/12: 7.5
H203
R/W
H004
R/W
2/4/6/8
H204
R/W
H006
R/W
0 to 255
H206
R/W
0 to 255
Parameter
R/W
No.
R
Trip monitor 1: Factor code
R
Trip monitor 1: Frequency
R
Trip monitor 1: Current
R
Trip monitor 1: Voltage
d081
R
Trip monitor 1: Run time (H)
R
Trip monitor 1: Run time (L)
R
Trip monitor 1: ON time (H)
R
Trip monitor 1: ON time (L)
R
Trip monitor 2: Factor code
R
Trip monitor 2: Frequency
R
Trip monitor 2: Current
R
Trip monitor 2: Voltage
d082
R
Trip monitor 2: Run time (H)
R
Trip monitor 2: Run time (L)
R
Trip monitor 2: ON time (H)
R
Trip monitor 2: ON time (L)
Data
Resolution
Data
Data
resolution
0.1 [Hz]
0.1 [%]
0.1 [V]
1. [h]
1. [h]
0.1 [Hz]
0.1 [%]
0.1 [V]
1. [h]
1. [h]
1.
1.