*1. Below are the contact specifications of the relay outputs.
Output terminal
Max. contact capacity
MA-MC
Min. contact capacity
Max. contact capacity
MB-MC
Min. contact capacity
Mode Selector
For the mounting position of each selector, refer to page 1-6.
<Input Logic Selector>
Available to switch the input logic (source or sink) in the multi-function input terminal circuit.
Symbol
Name
SR/SK
Input logic selector
<RS-485 Communication/Operator Selector>
Select the mode according to the option connected to the communications connector.
When using the 3G3AX-OP01 supplied with the Inverter, it is available regardless of the switch
condition.
Symbol
Name
RS-485 communication/
485/OPE
operator selector
Resistance load
250 V AC, 2 A
30 V DC, 3 A
100 V AC, 10 mA
5 V DC, 100 mA
250 V AC, 1 A
30 V DC, 1 A
100 V AC, 10 mA
5 V DC, 100 mA
Status
SR
Source logic
SK [Default]
Sink logic
Status
485
ModBus communication
OPE [Default]
Digital Operator (Option: 3G3AX-OP01)
2-3 Wiring
Inductive load
250 V AC, 0.2 A
30 V DC, 0.6 A
250 V AC, 0.2 A
30 V DC, 0.2 A
Description
Description
2
2-24