Table 13. LCD Message Troubleshooting Table
Displayed Message
DIAGNOSTIC
No
PASSED
DO NOT POWER OFF
No
DP FIFO Busy*
Yes
DRVR CIR BAD*
No
E00 EXE @ ADDR0
Yes
See User Manual
E01A TYPE 0x40
Yes
See User Manual
Can User
Explanation
Correct?
Status message: the
printer passed its
memory and hardware
initialization tests.
Status message: The
printer is performing an
operation that must be
completed before you
can cycle power.
There is a timing problem
in the Engine Controller
firmware.
Driver Circuit Bad. The
hammer coil count test
failed.
An illegal or unsupported
instruction was attempted
in the application
program.
An illegal or unsupported
instruction was attempted
in the application
program.
Fault Messages
Solution
No action is required.
No action is required, but do not
power off the printer until the
operation is complete.
1.
Cycle power. Run the print job
again. If the message appears,
download the emulation
software again.
2.
Cycle power. Run the print job
again. If the message appears
again, contact your authorized
service representative.
Contact your authorized service
1
representative.
1.
Cycle Power. Run the print job
again. If the message appears,
load the latest emulation
software.
2.
Cycle power. Run the print job
again. If the message appears,
record the display message
and send it to your next higher
support facility.
1.
Cycle Power. Run the print job
again. If the message appears,
load the latest emulation
software.
2.
Cycle power. Run the print job
again. If the message appears,
record the display message
and send it to your next higher
support facility.